PIPE FIRE SLEEVES
 

Firefly 109 Pipe Fire Sleeves are an intumescent solution providing fire and acoustic protection to combustible and non-combustible pipes, ventilation ducting and cable bunches when penetrating fire rated walls or floors.

The FF109 Pipe Fire Sleeves are ready to install providing a quick and easy solution without the need for foams, mastic or sealant. The Sleeves allow an effective fire, acoustic and thermal seal to be achieved in one visit, replacing the labour intensive over sleeving method.

Pipe Fire Sleeves


The unique Fire Sleeve design allows for thermal movement whilst providing a vapour seal. In a fire situation, the intumescent material will crush and seal off plastic services replacing traditional pipe wraps and fire collars or provide a fire seal around metal services.

The FF109 Pipe Fire Sleeves are available for pipe diameters ranging from 15 mm up to 169 mm.

 
Applications
 
  • Pipe Penetrations
  • Circular Ventilation Ducting
  • Cable Bunches
  • Fire Resistant Walls/Floors
  • Acoustically Rated Walls/Partitions
 
Properties
 
  • 2 Hour Fire Rated
  • Labour Saving
  • Acoustic Rated
  • No over sleeving required
  • Full range of sizes
  • Dry system - no need for additional sealants
 
Fire Testing Approvals
 
2 Hour Fire Tested to BS476: Part 20: 1987
Suitable for Plasterboard Partitions, Solid Walls/Floors and Mineral Fibre Batts
Assessment No.: Chilt/03187 Rev D / Chiltern Int. Fire.
 
Acoustic Testing Approvals
 
Tested in accordance with BS EN ISO 140-3:1995 and BS EN ISO 717-1:1997 under
UKAS conditions in a plasterboard partition construction.
Test No.: 239037 / Building Research Establishment (BRE).
 
Regulations
 
Meets the requirements of UK Building Regulations Approved Document B and E and HTM2045.
 
To ask questions or receive information about Pipe Fire Sleeves, please use the form below.
 
Name
Company
Telephone
Email
Enquiry
 
 
 
 
cable passthrough system suppliers pipe bandageand canisters downlighter protection covers ventilation grill manufacturer intumescent slabs intumescent pillows cable tray blocks fire protection boards complete fire protection fireplug fire protection materials cable passthrough system suppliers pipe bandages and canisters downlighter protection covers ventilation grill manufacturer intumescent slabs intumescent pillows cable tray blocks fire protection boards